The One Series electronic pressure and temperature transmitter-switches set the standard for smart digital process monitoring. With a fully adjustable set point and deadband and 0.1% repeatability, the One Series performs in a wide variety of applications. Available in Type 4X enclosures approved for intrinsic safety, flameproof and non-incendive area classifications, these hybrid transmitter-switches are designed to provide transmitter, switch and gauge functions all-in-one rugged enclosure that can withstand the rigors of harsh and hazardous environments.

Công tắc áp suất 1XSWLL United Electric

Các sản phẩm khác của United Electric

Features

  • Digital process and status display
  • Fully adjustable set point and deadband
  • Local and remote self-diagnostic reporting
  • Agency certifications for hazardous locations
  • cULus, IECEx, GOST, CE and ATEX
  • Class I, Division 1 & 2 models available
  • Zones 0, 1 & 2
  • 3 ways to power the control –
  • 2-wire discrete input power
  • Loop-powered analog input
  • External power supply
  • 2 ways to program the control –
  • Local keypad and display
  • Remote HART® communicator
  • Multiple sensor types and ranges –
  • Gage pressure from full vacuum up to 6000 psi (413,7 bar)
  • Differential pressure up to 200 psid (13,8 bar d)
  • RTD temperature from -300 to 1,000°F (-184 to 538°C)
  • 3 models to choose from
  • 2-wire low power single switch (only)
  • Loop-powered Hart Transmitter plus 2 solid-state relays
  • Loop-powered Hart Transmitter (only)

Power input/ Switch capacity:

Model Maximum Power Ratings / Output Signal Set Point Switch Ratings (SPST) IAW™ Switch  Ratings (SPST) Min. Load Requirement Off State Leakage
1XSWLL 2-wire 7.8 – 50 VDC discrete input powered @ 0.75 mA 7.8 – 50 VDC @ 0.1 A MOSFET derate @ 1 mA per °C > 25°C 7.8 – 50 VDC @ 0.1 A MOSFET derate @ 1 mA per °C > 25°C 2.7 mA 0.8 mA
1XSWHL 2-wire 70 – 240 VAC & VDC @ 1 mA discrete input powered  70 – 240 VAC/VDC @
0.1 A
7.8 – 50 VDC @ 0.1 A 6.0 mA 1 mA
1XSWHH 4-wire 70 – 240 VAC
@ 6 mA external
power supply 
70 – 240 VAC @ 0.15
– 10 A
7.8 – 50 VDC @ 0.1 A 0.15 A 0.1 mA
1XTXSW 2-wire 20 – 40 VDC
@ 21 mA / Loop powered 4-20 mA analog output with HART® version 7
SW1 & SW2: 0 – 280 VAC & VDC @ 0.3 A derate 8% per 10°C >
21°C
0 – 30 VDC @ 0.020 A MOSFET   0 mA 0.01 mA
1XTX00 2-wire 20 – 40 VDC
@ 21 mA / Loop powered 4-20 mA analog output with HART® version 7
N/A N/A N/A N/A

Phạm vi nhiệt độ:

  Approved Ambient Operating Temperature Range
Model cULus (Division System) cULus & ATEX (zone System)
1XSWLL -40°F to 185°F (-40°C TO 85°C) -40°F to 185°F (-40°C to 85°C)
1XSWHL -40˚F to 185˚F (-40˚C to 85˚C) -40˚F to 185˚F (-40˚C to 85˚C)
1XSWHH -40˚F to 158˚F (-40˚C to 70˚C) -40˚F to 158˚F (-40˚C to 70˚C)
1XTXSW -40°F to 185°F (-40°C to 85°C) -40°F to 185°F (-40°C to 85°C)
1XTX00 -40°F to 185°F (-40°C to 85°C) -40°F to 185°F (-40°C to 85°C)

Oder:

Model Description zone Division
0 1 2 1 2
1XSWLL
(Replaces 2W2D,
2X2D, 2W4D,
2X4D)
• 2-wire, discrete input powered switch for 24 and 48 VDC
logic solver inputs
• Programmable set point switch rated at 7.8 - 50.0 VDC @
0.1 A max.
• IAW™ health status fail-safe-open switch rated at 7.8 -
50.0 VDC @ 0.1 A wired separately  to the logic solver
O O
1XSWHL (Replaces 2W3A and 2X3A) • 2-wire, discrete input powered switch for 110 and 230 VAC/VDC and 125 VDC logic solver inputs
• Programmable set point switch rated at 70 - 240 VAC/ VDC @ 0.1 A
• IAW™ health status fail-safe-open switch rated at 7.8 -
50.0 VDC @ 0.1 A wired separately  to the logic solver
 
1XSWHH (Replaces 4W3A and 4X3A) • 4-wire, external powered 70 - 240 VAC
• Programmable set point rated at 70 – 240 VAC @ 0.15
– 10 A
• IAW™ health status fail-safe-open switch rated at 7.8 -
50.0 VDC @ 0.1 A wired separately  to the logic solver
 
1XTXSW (Replaces 2WLP,
2XLP, 8W2D,
8X2D)
• Loop-powered 24 VDC HART® enabled smart transmitter
• Two programmable set point fail-safe solid state relays
rated at 0 - 280 VAC/VDC  @ 0.3 A
• IAW™ health status fail-safe-open switch rated at 0 -
30.0 VDC @ 0.020 A
 
1XTX00 (Transmitter Only) • Loop-powered 24 VDC HART® enabled smart transmitter  
  O - a safety barrier is required for intrinsically safe areas, Zone 0 and Div. 1 Ex ia
Bình luận của bạn
*
*
*
*
 Captcha
Chia sẻ:
Thống kê truy cập
  • Trực tuyến:
    3
  • Hôm nay:
    120
  • Tuần này:
    10396
  • Tuần trước:
    9114
  • Tháng trước:
    18792
  • Tất cả:
    2665490
Video Clip
Liên kết website

CÔNG TY TNHH TM VÀ DV TĂNG MINH PHÁT

  • Địa chỉ: Số 1, Đường số 27, phường Hiệp Bình Chánh, Quận Thủ Đức, Tp.HCM.

  • Hotline: 0917.000.655 (Mr.Hue)

  • Email: hue@tmpvietnam.com

  • Zalo: 0917.000.655

  • Website: cuahangtudonghoa.com

MẠNG XÃ HỘI :  Thông tin cuối website Thông tin cuối website Thông tin cuối website Thông tin cuối website

© 2018 Tang Minh Phat , all rights reserved