VOAC7602 IWATSU VIỆT NAM
VOAC7523H IWATSU VIỆT NAM
VOAC7522H IWATSU VIỆT NAM
VOAC7521H IWATSU VIỆT NAM
VOAC7520H IWATSU VIỆT NAM
|
Number of digits
Full scale |
DCV |
CH-B
DCV |
ACV |
W |
DCA |
ACA |
Other functions |
VOAC7602 IWATSU
1ch |
61/2
1199999 |
0.1µV |
- |
0.1µV |
0.1mW |
1nA |
1µA |
Histogram /
trend display
Therm./ Freq./ Math. |
100mV -
1000V |
- |
100mV -
750V |
100Ω -
100MΩ |
1mA -
3A |
1A -
3A |
VOAC7523H IWATSU
2ch |
51/2
509999 |
0.1µV |
100µV |
1µV |
0.1mW |
10nA |
10nA |
Therm./ Freq./ Math. |
50mV -
1000V |
5V -
300V |
500mV -
750V |
50W -
500MW |
5mA -
10A |
5mA -
10A |
VOAC7522H IWATSU
1ch |
51/2
509999 |
0.1µV |
- |
1µV |
0.1mW
(2W/4W) |
10nA |
10nA |
Therm./ Freq./ Math. |
50mV -
1000V |
- |
500mV -
750V |
50W -
500MW |
5mA -
10A |
5mA -
10A |
VOAC7520H IWATSU
2ch |
51/2
509999 |
1µV |
100µV |
1µV |
0.1mW |
10nA |
10nA |
Therm./ Freq./ Math. |
500mV -
1000V |
5V -
300V |
500mV -
750V |
50W -
500MW |
5mA -
10A |
5mA -
10A |
VOAC7521H IWATSU
1ch |
51/2
509999 |
1µV |
- |
1µV |
0.1mW
(2W/4W) |
10nA |
10nA |
Therm./ Freq./ Math. |
500mV -
1000V |
- |
500mV -
750V |
50W -
500MW |
5mA -
10A |
5mA -
10A |
Digital Multimeter VOAC7602
Basic performances |
Display |
Display digit |
Measurement speed |
6 1/2 digits |
Full scale 1199999 |
50S/s
(60S/s Power Freq. at 60Hz) |
5 1/2 digits |
Full scale119999 |
30kS/s |
|
|
|
Measurements |
DC Voltage |
Range |
100mV - 1000V |
Input impedance |
1GΩ or more, or 10MΩ |
Input bias current |
<30pA |
AC Voltage |
Range |
100mV - 750V |
Frequency |
20Hz - 300kHz |
Crest Factor |
Less than 5 |
Input impedance |
1MΩ //100pF |
AC filter |
20Hz, 200Hz |
Resistance(2WΩ4WΩ) |
Range |
100Ω to 100MΩ |
DC current |
Range |
1mA to 3A |
AC current |
Range |
1A,3A |
Continuity measurement (CONT) |
Yes |
Diode measurement (DIODE) |
Frequency measurement (FREQ) |
3Hz to 300kHz |
Temperature measurement (TEMP) |
Thermocouple (TYPE- R, K, T, J ,E) Manual input of
cold junction temperature , RTD (2-wire or 4-wire) |
|
Interfaces |
Standard |
USB2.0 |
Optional |
LAN&RS-232(SC-361) / DIO(SC-362) / GPIB(SC-363) |
|
Functions |
Difference operation (NULL) |
Yes |
Moving average operation |
2 - 100 times |
Statistical calculation (MAX/MIN/AVG/SDT) |
Yes |
LIMIT judgment |
Scaling operation |
Decibel operation |
Measurement data memory(logging) |
100k Readings |
Pre-triggering / level triggering |
Supported by the latest firmware |
Panel setup memory |
Internal 10 + USB Storage memory |
Panel setup sequence |
Internal memory (Optional RS-232 is required) |
Analog meter display |
Yes |
Panel lock function |
Interval measurement |
Trend chart display |
Real Time |
Yes |
Offline |
Supported by the latest firmware |
Cursor & Search |
Histogram display |
Real Time |
Yes |
Offline |
Supported by the latest firmware |
Cursor & Search |
USB host |
Panel setup, measurement data and hard copy can be stored in USB memory |
|
Dimension / Weight |
Dimension (mm) |
Approx. 225W × 100H × 366D(Excluding the protrusion part)
Approx. 213W × 88H × 356D (Excluding the protector part) |
Weight |
Approx. 3kg |
Protector |
Yes |
|
Others |
Operating temperature and humidity range |
0°C to 50°C (+40°C 80% or less comparable volume water) and no condensing |
Storage temperature and humidity range |
-20°C to +60°C (+40°C 90% or less comparable volume water)and no condensing |
Power supply and Power consumption |
AC100V,50/60Hz, less than 21 VA
110V / 220V / 240V(Optional) |
Accessories |
Test leads, Fuse, CD-ROM Operation manual, Power cord |
|
Digital Multimeters VOAC7523H / VOAC7522H / VOAC7520H / VOAC7521HSpecifications
* |
Accuracy (±X% of reading +Y digits) indicated by X+Y |
|
The measuring accuracy indicated below can be obtained for a year following the calibration of the instrument. |
1. Typical Sample Rate and Resolution |
|
Sample Rate |
Resolution |
Reading Rate |
Hum Rejection |
SLOW |
5.5-digit |
approx. 4 times/sec |
Yes |
MID |
5.5-digit |
approx. 20 times/sec |
Yes |
FAST |
4.5-digit |
approx. 100 times/sec |
N/A |
|
|
2. DC Volt (DCV) 50mV range is for the VOAC7523H / 7522H only. |
|
Range |
Resolution |
Input Resistance |
Accuracy* |
5.5-digit |
4.5-digit |
SLOW/MID |
FAST |
50mV |
0.1µV |
1µV |
100MW or more |
0.025+10 |
0.025+15 |
500mV |
1µV |
10µV |
1000MW or more |
0.012+5 |
0.012+10 |
5V |
10µV |
100µV |
0.012+2 |
0.012+7 |
50V |
100µV |
1mV |
approx. 10MW |
0.016+5 |
0.016+10 |
500V |
1mV |
10mV |
0.016+2 |
0.016+7 |
1000V |
10mV |
100mV |
|
The accuracy in the 50mV and 500mV ranges is specified after zero compensation through the REL operation. |
Sample rate in the 50mV range
SLOW/MID: Approx. 0.5 times/sec, FAST: Approx. 50 times/sec |
Max. input voltage: |
50mV to 5V range ± 800V (continuous)
50V to 1000V range ± 1100V (continuous) |
Resolution and noise rejection |
Resolution |
Sample Rate |
NMRR |
CMRR |
5.5-digit |
SLOW |
55dB or more |
120dB or more |
5.5-digit |
MID |
55dB or more |
120dB or more |
4.5-digit |
FAST |
0dB |
55dB or more |
|
|
3. CH-B DC Volt (DCV) VOAC7523H / 7520H only |
|
Range |
Resolution |
Input Resistance |
Accuracy* |
4.5-digit |
SLOW/MID |
FAST |
5V |
100µV |
CH-B:H to CH-B:L 10MW ± 3%
CH-B:H to CH-A:L 5MW ± 3%
CH-B:L to CH-A:L 5MW ± 3% |
0.025+2 |
0.025+30 |
50V |
1mV |
0.025+8 |
300V |
10mV |
0.025+5 |
|
Max. input voltage: |
± 300V, between CH-A L and CH-B ± 300V |
Resolution and noise rejection |
Resolution |
Sample Rate |
NMRR |
CMRR |
Isolation between CH-A and CH-B |
4.5-digit |
SLOW/MID |
55dB or more |
120dB or more |
56dB or more |
4.5-digit |
FAST |
0dB |
55dB or more |
|
|
4. AC Volt (ACV, DC+ACV) detection of True RMS
Up to 100kHz for VOAC7521H / 7520H |
|
Range |
Resolution |
Measurement Range |
Input Resistance |
5.5-digit |
SLOW |
MID/FAST |
500mV |
1µV |
15Hz to 300kHz |
200Hz to 300kHz |
less than approx.
1MW // 100pF |
5V |
10µV |
50V |
100µV |
500V |
1mV |
45Hz to 100kHz |
200Hz to 100kHz |
750V |
10mV |
45Hz to 20kHz |
200Hz to 20kHz |
|
Accuracy: SLOW Sample (Sine wave Amplitude at 5% to 100% of fullscale of range) |
Frequency |
Accuracy* |
15Hz to 45Hz |
0.5+150 |
45Hz to 100Hz |
0.25+150 |
100Hz to 30kHz |
0.2+150 |
30kHz to 100kHz |
0.5+300 |
100kHz to 300kHz |
2.5+1000 |
|
Coefficient to input other than sine wave |
Crest Factor |
Crest Factor |
1 to 1.5 |
1.5 to 2 |
2 to 3 |
15Hz to 30kHz |
0.05% |
0.15% |
0.30% |
30kHz to 300kHz |
0.20% |
- |
- |
|
Sample Rate |
Resolution |
Reading Rate |
Response Time |
SLOW |
5.5-digit |
4 times/sec |
less than 3 sec |
MID/FAST |
5.5-digit |
20 times/sec |
less than 2 sec |
|
Max. input voltage: 780Vrms, ± 1100V DC (continuous) |
In the case of DC+ACV, 500 (less than 45Hz) or 300 (45Hz or higher) must be added to the value of Accuracy digit in above. |
Sample rate of FAST becomes the same values as MID (approx. 20 times/sec). |
|
5. DC Current (DCA) |
|
Range |
Resolution |
Accuracy* |
Input Resistance |
5.5-digit |
4.5-digit |
SLOW/MID |
FAST |
5mA |
10nA |
100nA |
0.05+7 |
0.05+17 |
150W or less |
50mA |
100nA |
1µA |
15W or less |
500mA |
1µA |
10µA |
2W or less |
10A |
100µA |
1mA |
0.2+7 |
0.2+17 |
0.1W or less |
|
Auto range is not available between 5mA to 500mA range and 10A range because of using different input terminals. |
Max. input current: |
500mA at 5mA to 500mA ranges (FUSE 0.5A/250V)
10A at 10A range (FUSE 15A/250V) |
|
6. AC Current (ACA, DC+ACA) |
|
Range |
Resolution |
Measurement Range |
Input Resistance |
5.5-digit |
SLOW/MID |
FAST |
5mA |
10nA |
15Hz to 5kHz |
200Hz to 5kHz |
150W or less |
50mA |
100nA |
15W or less |
500mA |
1µA |
45Hz to 5kHz |
2W or less |
10A |
100µA |
0.1W or less |
|
Accuracy: SLOW Sample (Sine wave) amplitude at 5% to 100% of fullscale (10% to 100% for10A range) |
Frequency |
Accuracy* |
Crest Factor |
1 to 1.5 |
1.5 to 2 |
2 to 3 |
15Hz to 45Hz |
1+200 |
0.05% |
0.15% |
0.30% |
45Hz to 1kHz |
0.4+200 |
1kHz to 5kHz |
5.0+200 |
|
Sample Rate |
Resolution |
Reading Range |
Response time |
SLOW |
5.5-digit |
4 times/sec |
less than 3 sec |
MID/FAST |
5.5-digit |
20 times/sec |
less than 2 sec |
|
Max. input current: |
500mA for 5mA to 500mA ranges (FUSE 0.5A)
10A for 10A range (FUSE 15A) |
DC Component on input current must be included in the Max. input current. |
In the case of 10A range at 45Hz to 1kHz, 0.3 must be added to %. |
In the case of DC+ACA, 500 (less than 45Hz) or 300 (45Hz or higher) must be added to the value of Accuracy in above. |
Sample rate of FAST becomes the same value as MID (approx. 20 times/sec). |
|
7. Resistance (2 WireW/4 WireW) 4 WireW: VOAC7522H / 7521H only |
|
Range |
Resolution |
Accuracy* |
Test Current |
SLOW/MID |
FAST |
SLOW/MID |
FAST |
50W |
0.1mW |
1mW |
0.025+10 |
0.025+15 |
approx. 10mA |
500W |
1mW |
10mW |
0.014+3 |
0.014+8 |
approx. 10mA |
5kW |
10mW |
0.1W |
approx. 1mA |
50kW |
0.1W |
1W |
approx. 100µA |
500kW |
1W |
10W |
0.015+3 |
0.015+33 |
approx. 10µA |
5MW |
10W |
10W |
0.033+30 |
0.033+30 |
approx. 1µA |
50MW |
100W |
100W |
0.25+30 |
0.25+30 |
approx. 100nA |
500MW |
1kW |
1kW |
1.5+50 |
1.5+50 |
approx. 10nA |
|
Max. input voltage: ± 500V peak |
Open circuit test voltage: 12V or less |
The accuracy at 50W to 5kW range are specified after zero compensation through the REL operation. |
Sample rate of FAST at 5MW to 500MW range becomes the same value as MID (approx. 20 times/sec). |
|
8. Low-Power Resistance (2 WireW) |
|
Range |
Resolution |
Accuracy* |
Test Current |
SLOW/MID/FAST |
SLOW/MID |
FAST |
500W |
10mW |
0.1+5 |
0.1+15 |
approx. 1mA |
5kW |
0.1W |
approx. 100µA |
50kW |
1W |
approx. 10µA |
500kW |
10W |
0.2+30 |
0.2+40 |
approx. 1µA |
5MW |
100W |
0.2+30 |
approx. 100nA |
50MW |
1kW |
1.5+30 |
1.5+30 |
approx. 10nA |
|
Max. input voltage: ± 500V peak |
Open circuit test voltage: 12V or less |
The accuracy at 500W to 5kW range are specified after zero compensation through the REL operation. |
Sample rate of FAST at 5MW to 500MW range becomes the same value as MID (approx. 20 times/sec). |
Indications are in 4.5 digits for SLOW, MID, and FAST. |
|
9. Diode |
|
Test Current |
Measurement Range |
Accuracy* |
Open Circuit Test Voltave |
Max. Input Voltave |
approx. 1mA or 10mA |
0.1mV to 5.0999V |
0.014+13 |
12V or less |
± 500V peak |
|
|
10. Temperature |
|
Thermocouple |
Temperature Range to be Measured |
Accuracy* |
Resolution |
Max. Input Voltave |
R |
-50°C to 0°C |
0.2+70 |
0.1°C |
± 500V peak |
0°C to +100°C |
0.2+50 |
+100°C to +1768°C |
0.2+30 |
K(CA) |
-200°C to -100°C |
0.15+50 |
-100°C to 0°C |
0.15+35 |
0°C to +1372°C |
0.15+20 |
T(CC) |
-200°C to -100°C |
0.15+50 |
-100°C to 0°C |
0.15+35 |
0°C to +400°C |
0.15+20 |
J(IC) |
-200°C to -100°C |
0.15+50 |
-100°C to 0°C |
0.15+35 |
0°C to +1200°C |
0.15+20 |
E(CRC) |
-200°C to -100°C |
0.15+50 |
-100°C to 0°C |
0.15+35 |
0°C to +1000°C |
0.15+20 |
|
The above accuracy values do not include the thermocouple accuracy.
±0.1°C/°C is added (for all thermocouples) with the operating ambient temperature of this product at 0°C to 18°C and 28°C to 50°C.
accuracy is not specified. In the temperature range to be measured at -200°C or lower,
The reference thermo electric force is calculated by the "broken line approximation" according to JIS C 1602-1995.
If this product and the thermocouple are connected via a plug, an error for contact temperature compensation is added.
|
|
11. Frequency (AC couple, Crest Factor: less than 3) |
|
Sample Rate |
Reading Rate
(Gate time) |
Display Digits and Measurement Range |
Accuracy* |
SLOW |
approx. 0.5 times/sec (1s) |
6-digit |
15.0000Hz to 1.00000MHz |
0.02+2 |
MID |
approx. 4 times/sec (100ms) |
5-digit |
15.000Hz to 1.0000MHz |
FAST |
approx. 10 times/sec (10ms) |
4-digit |
150.00Hz to 1.000MHz |
|
AC couple: Crest factor <=3
AUTO range of ACV must be used with input attenuator.
Max. input voltage: 780 Vrms, ± 1100V peak
|
|
12. Chart for combination of Dual Function |
|
|
DCV |
CH-B
DCV (*1) |
ACV |
DC+
ACV |
DCA |
ACA |
DC+
ACA |
2 WireW |
4 WireW(*2) |
Hz |
°C |
DCV |
|
|
|
|
|
|
|
|
|
|
|
CH-B
DCV (*1) |
|
|
|
|
|
|
|
|
- |
|
|
ACV |
|
|
|
|
|
|
|
|
|
|
|
DC+ACV |
|
|
|
|
|
|
|
|
|
|
|
DCA |
|
|
|
|
|
|
|
|
|
|
|
ACA |
|
|
|
|
|
|
|
|
|
|
|
DC+ACA |
|
|
|
|
|
|
|
|
|
|
|
2 WireW |
|
|
|
|
|
|
|
|
|
|
|
4 WireW(*2) |
|
- |
|
|
|
|
|
|
|
|
|
Hz |
|
|
|
|
|
|
|
|
|
|
|
°C |
|
|
|
|
|
|
|
|
|
|
|
|
(*1) CH-B DCV: VOAC7523H / 7520H only |
(*2) 4 WireW: VOAC7522H / 7521H only |
|
13. General |
|
MATH |
Moving Average, Scale, Decibel (dBm, dBµ), Difference, Statistics (MAX, MIN, , s), Comparison (COMP), Arithmetic Calculation between Dual Function |
Memory |
DATA |
Max. 3000 data with 10 msec resolution time mark (Elapsed time) |
SET UP |
10 |
Interfaces (Full Remote) |
Standard |
RS-232 |
Option |
LAN, GP-IB |
Power Supply |
Voltage |
AC100V, 110V, 220V, 240V |
Frequency |
50Hz, 60Hz |
Power Consumption |
21 VA (includes options) or less |
Operation Temperature and Humidity |
0°C to +50°C (less than 80%RH)
no condensation, 70%RH or less at +40°C to +50°C |
Storage Temperature and Humidity |
-20°C to +60°C (70%RH or less)
no condensation, includes operation temperature |
Size |
Measurement |
210W x 99H x 353L mm (Options are built into the main unit) |
Weight |
3.5kg (includes options) or less |
Standard Accessories |
Fuse, Test Leads, Alignment Screwdriver, Operation Manual(CD-ROM), Power cord |
|
|