DMP335 Pressure Transmitter SensorsONE

DMP 335 là cảm biến áp suất bằng thép không gỉ có thể làm việc được trong môi trường khắc nhiệt nhưng vẫn không ảnh hưởng đến tuổi thọ và hiệu quả làm việc.

DMP335 Pressure Transmitter - SensorsONE Việt Nam

Product Parameters

  • Pressure Range: 0…6 to 0…600 bar gauge
  • Output Signal: 2 wire 4-20mA, 3 wire 0-10Vdc
  • Accuracy: 0.5% FS
  • Electrical Connection: DIN plug, Binder 723, IP67/68 cable gland, M12 connector, field housing
  • Process Connection: G1/4 or G12 EN837, ¼ NPT male
  • Media Compatibility: Stainless steel – 17-4PH diaphragm, 316Ti pressure port
  • Special Features: Dry sensor construction, high overpressure, Oxygen applications
  • Special Options: ATEX & IECEx intrinsic safety

GX_700 Teclock IRHD automatic rubber hardness tester

Input pressure range
Nominal pressure gauge        [bar] 6 10 16 25 40 60 100 160 250 400 600
Overpressure                         [bar] 14 35 35 70 140 140 350 350 700 1200 1200
Burst pressure ≥                     [bar] 35 85 85 175 350 350 850 850 1750 2100 2100
Vacuum resistance unlimited
Output signal / Supply
Standard 2-wire:       4 ... 20 mA   /   VS =   8 ... 32 VDC
Option IS-version 2-wire:      4 ... 20 mA   /   VS = 10 ... 28 VDC
Option 3-wire 3-wire:       0 ... 10 V      /   VS = 14 ... 30 VDC
Performance
Accuracy 1 ≤ ± 0.5 % FSO
Permissible load current 2-wire:    Rmax = [(VS VS min) / 0.02 A] W
voltage 3-wire:    Rmin = 10 kW
Influence effects supply:   0.05 % FSO / 10 V
load:       0.05 % FSO / kW
Long term stability ≤ ± 0.2 % FSO / year at reference conditions
Response time 2-wire: £ 10 msec
3-wire: £ 3 msec
1 accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability)
Thermal effects (Offset and Span)
Thermal error ± 0.3 % FSO / 10 K
in compensated range 0 … 70 °C
Permissible temperatures
Permissible temperatures medium:                                    -40 ... 125 °C
electronics / environment:        -40 ...   85 °C
storage:                                    -40 ... 100 °C
Electrical protection
Short-circuit protection permanent
Reverse polarity protection no damage, but also no function
Electromagnetic compatibility emission and immunity according to EN 61326
Mechanical stability
Vibration 20 g RMS (25 ... 2000 Hz)         according to DIN EN 60068-2-6
Shock 500 g / 1 msec                            according to DIN EN 60068-2-27
Materials
Pressure port stainless steel 1.4571 (316 Ti)
Housing stainless steel 1.4404 (316 L)
Option compact field housing stainless steel 1.4305 (303), cable gland brass, nickel plated              others on request
Seals (media wetted) none (welded)
Diaphragm stainless steel 1.4542 (17-4PH)
Media wetted parts pressure port, diaphragm
Explosion protection (only for 4 … 20 mA / 2-wire)
Approvals
DX19-DMP 335
IBExU 10 ATEX 1068 X   /  IECEx IBE 12.0027X
zone 0:         II 1G Ex ia IIC T4 Ga
zone 20:       II 1D Ex ia IIIC T 85°C Da
Safety technical maximum values Ui = 28 VDC, Ii = 93 mA, Pi = 660 mW, Ci 0 nF, Li 0 mH,
the supply connections have an inner capacity of max. 27 nF to the housing
Permissible temperatures for
environment
in zone 0:     -20 ... 60 °C bei patm 0.8 bar up to 1.1 bar in zone 1:     -20 ... 70 °C
Connecting cables (by factory) cable capacitance:       signal line/shield also signal line/signal line: 160 pF/m
cable inductance:        signal line/shield also signal line/signal line: 1 mH/m
Miscellaneous
Current consumption signal output current:      max. 25 mA
signal output voltage:      max. 7 mA
Weight approx. 140 g
Installation position any
Operational life > 100 x 106 pressure cycles
CE-conformity EMC Directive: 2014/30/EU
Pressure Equipment Directive: 2014/68/EU (module A) 2
ATEX Directive 2014/34/EU
2 This directive is only valid for devices with maximum permissible overpressure > 200 bar
Wiring diagrams
2-wire-system (current)

supply +
p

VS

supply I
3-wire-system (voltage)

supply +
p
VS

supply

U    signal +                               V
Pin configuration
Electrical connections ISO 4400 Binder 723 (5-pin) M12x1 (4-pin) field housing cable colour
(IEC 60757)
Supply +
Supply Signal + (only for 3-wire)
1
2
3
3
4
1
1
2
3
IN +
IN OUT +
wh (white)
bn (brown)
gn (green)
Bình luận của bạn
*
*
*
*
 Captcha
Chia sẻ:
Thống kê truy cập
  • Trực tuyến:
    2
  • Hôm nay:
    408
  • Tuần này:
    4768
  • Tuần trước:
    13243
  • Tháng trước:
    16567
  • Tất cả:
    2671661
Video Clip
Liên kết website

CÔNG TY TNHH TM VÀ DV TĂNG MINH PHÁT

  • Địa chỉ: Số 1, Đường số 27, phường Hiệp Bình Chánh, Quận Thủ Đức, Tp.HCM.

  • Hotline: 0917.000.655 (Mr.Hue)

  • Email: hue@tmpvietnam.com

  • Zalo: 0917.000.655

  • Website: cuahangtudonghoa.com

MẠNG XÃ HỘI :  Thông tin cuối website Thông tin cuối website Thông tin cuối website Thông tin cuối website

© 2018 Tang Minh Phat , all rights reserved