Đồng hồ đo lưu lượng FT3 Fox Thermal | Flow Meter FT3 Fox Thermal
Công Ty TNHH TM và DV Tăng Minh Phát chuyên cung cấp đồng hồ đo lưu lượng hãng Fox Thermal tại Việt Nam
The Model FT3 was designed with our oil and gas customers in mind. This meter is Quad O (OOOO) compliant and is perfect for use in flare gas applications along with other fuel gas measurement.
Đồng hồ đo lưu lượng FT3 Fox Thermal
Đồng hồ đo lưu lượng FT3 của Fox Thermal:
- Measures process gas flow rate/total and temperature
- A USB connection is standard (free FT3 View™ Software); Optional HART and Modbus RTU (RS485) communication protocols
- Optional on-board display and configuration panel
- Equipped with the Power Pro™ thermal mass flow sensor
- One discrete output is programmable for either pulse (for totalizing flows) or alarms
- One discrete input to reset total or select a different calibration on 2 gas curves
- 4-20mA output proportional to mass flow rate
- Click the Approvals tab for Model FT3 Agency Approvals.
- Calibration Validation with the CAL-V™ and Zero CAL-CHECK® features.
- NIST-traceable calibration
- Wide measurement range
- 1% R + 0.2% FS flow accuracy
- 24 VDC or optional 100 to 240VAC in local or remote enclosures
Order
FT3-06IE-SS-ST-E1-D0-B0-G1 FT3-06IE-SH-SH-E2-DD-B1-G2 FT3-06IE-SJ-ST-E3-DL-MB-G3
FT3-06IE-SL-SH-E4-D0-BH-G4 FT3-06IE-SH-ST-E1-DD-B1-G5 FT3-06IE-SJ-SH-E2-DL-MB-G6
FT3-06IE-SL-ST-E3-D0-BH-G7 FT3-09I-SS-ST-E1-D0-B0-G1 FT3-09I-SH-ST-E1-DD-B1-G4
FT3-09I-SJ-ST-E3-DL-MB-G3 FT3-09I-SL-SH-E2-DL-BH-G3 FT3-09I-SH-ST-E3-DD-B1-G5
FT3-09I-SJ-SH-E4-D0-MB-G7 FT3-09I-SL-ST-E4-D0-BH-G7 FT3-12I-SS-ST-E1-D0-B0-G1
FT3-12I-SH-ST-E2-DD-B1-G2 FT3-12I-SJ-ST-E3-DL-MB-G3 FT3-12I-SL-SH-E4-DD-BH-G4
FT3-12I-SH-ST-E1-DD-BH-G5 FT3-12I-SJ-SH-E3-DL-MB-G5 FT3-12I-SL-ST-E3-D0-BH-G7
FT3-15I-SS-ST-E1-D0-B0-G2 FT3-15I-SH-SH-E2-DD-B1-G2 FT3-15I-SJ-ST-E3-DL-MB-G3
FT3-15I-SL-SH-E3-D0-BH-G4 FT3-15I-SH-SH-E1-DD-B1-G5 FT3-15I-SJ-SH-E2-DL-MB-G6
FT3-15I-SL-ST-E3-D0-B0-G7 FT3-18I-SS-ST-E1-D0-B0-G2 FT3-18I-SH-SH-E2-DD-B1-G2
FT3-18I-SJ-ST-E3-DL-MB-G3 FT3-18I-SL-SH-E3-D0-BH-G4 FT3-18I-SH-SH-E1-DD-B1-G5
FT3-18I-SJ-SH-E2-DL-MB-G6 FT3-18I-SL-ST-E3-D0-B0-G7 FT3-24I-SS-ST-E1-D0-B0-G2
FT3-30I-SH-SH-E2-DD-B1-G2 FT3-24I-SJ-ST-E3-DL-MB-G3 FT3-36I-SL-SH-E3-D0-BH-G4
FT3-24I-SH-SH-E1-DD-B1-G5 FT3-30I-SJ-SH-E2-DL-MB-G6 FT3-36I-SL-ST-E3-D0-B0-G7
FT3-24R-SS-ST-E1-D0-B0-G2 FT3-30R-SH-SH-E2-DD-B1-G2 FT3-15R-SJ-ST-E3-DL-MB-G3
FT3-36R-SL-SH-E3-D0-BH-G4 FT3-24R-SH-SH-E1-DD-B1-G5 FT3-30R-SJ-SH-E2-DL-MB-G6
FT3-36R-SL-ST-E3-D0-B0-G7 FT3-R1-SS-ST-E1-D0-B0-G2 FT3-R2-SH-SH-E2-DD-B1-G2
FT3-R3-SJ-ST-E3-DL-MB-G3 FT3-R1-SL-SH-E3-D0-BH-G4 FT3-R2-SH-SH-E1-DD-B1-G5
FT3-R3-SJ-SH-E2-DL-MB-G6 FT3-R1-SL-ST-E3-D0-B0-G7
Thông số kỹ thuật đồng hồ đo lưu lượng FT3
Technical Specifications | ||||||
Fox Thermal Model FT3 Thermal Mass Flow Meter & Temperature Transmitter | ||||||
Performance Specs | ||||||
Type | Insertion | Inline | ||||
Flow Accuracy: | ± 1% of reading ± 0.2% of full scale. | ± 1% of reading ± 0.2% of full scale. | ||||
15 diameters of straight, unobstructed pipe upstream and 10 downstream. | 8 diameters of straight, unobstructed pipe upstream and 4 downstream. | |||||
Flow Repeatability: | ± 0.2% of full scale | |||||
Flow Response Time: | 0.9 seconds (one time constant) | |||||
Temperature Accuracy: | ± 1.8°F (± 1.0°C) -40 to 250°F (-40 to 121°C); ± 3.6°F (± 2.0°C), 250 to 650°F (121 to 343°C); 60 SFPM minimum. | |||||
Calibration: | Factory Calibration to NIST-traceable standards | |||||
CAL-V™ and Zero CAL-CHECK®: In situ, operator-initiated calibration validation | ||||||
Operating Specs | ||||||
Type | Insertion | Inline | ||||
Flow Units (field selectable): | SCFM, SCFH, NMPS, NM3/M, NM3/H, NM3/D, NLPS, NLPM, NLPH, MCFD, MSCFD, SCFD, MMSCFD, MMSCFM, SMPS, SM3/H, LB/S, LB/M, LB/H, LB/D, KG/S, KG/M, KG/H, SLPM, SFPM, MT/H, SM3/M | |||||
Flow Rates: | 15 to 60,000 SFPM (0.07 to 280 NMPS) - Air at 70°F (20°C) & 1 ATM | |||||
Turndown: | up to 1000:1; 100:1 typical | |||||
Flow Ranges: | Pipe Size | SCFM | NM³/Hr | Pipe Size | SCFM | NM³/Hr |
1.5" (40mm) | 0 - 840 | 0 - 1,325 | 0.25" | 0 - 7.5 | 0 - 11.8 | |
2" (50mm) | 0 - 1,400 | 0 - 2,210 | 0.5" | 0 - 125 | 0 - 200 | |
2.5" (63mm) | 0 - 2,000 | 0 - 3,150 | 0.75" | 0 - 220 | 0 - 350 | |
3" (80mm) | 0 - 3,100 | 0 - 4,890 | 1" | 0 - 360 | 0 - 570 | |
4" (100mm) | 0 - 5,300 | 0 - 8,360 | 1.25" | 0 - 625 | 0 - 990 | |
6" (150mm) | 0 - 12,000 | 0 - 18,930 | 1.5" | 0 - 840 | 0 - 1,325 | |
8" (200mm) | 0 - 20,840 | 0 - 32,870 | 2" | 0 - 1,400 | 0 - 2,210 | |
10" (250mm) | 0 - 32,800 | 0 - 51,740 | 2.5" | 0 - 2,000 | 0 - 3,150 | |
12" (300mm) | 0 - 46,600 | 0 - 73,500 | 3" | 0 - 3,100 | 0 - 4,890 | |
4" | 0 - 5,300 | 0 - 8,360 | ||||
6" | 0 - 12,000 | 0 - 18,930 | ||||
Note: Standard conditions of air at 70°F and one atmosphere. | ||||||
Consult factory for other gases, pipe sizes, and flow ranges other than those listed. | ||||||
Gas Pressure (max): | 500 psig (34.5 barg) | 316 SS inline w/NPT ends: 300 psig (20 barg) | ||||
316 SS inline w/150lb flanges: 230 psig (16 barg) | ||||||
CS inline w/NPT ends: 300 psig (20 barg) | ||||||
CS inline w/150lb flanges: 285 psig (20 barg) | ||||||
Check with factory for higher pressure options. | ||||||
Note: Pressure ratings stated for temperature of 100°F (38°C). | ||||||
Relative Humidity: | 90% RH maximum; non-condensing | |||||
Temperature by Sensor Type: (see Approvals tab) | ST Sensor: -40 to 250°F (-40 to 121°C) | |||||
HT Sensor: -40 to 650°F (-40 to 343°C) | ||||||
Temperature by Enclosure: (see Approvals tab) | Without display or AC power supply: -40 to 158°F (-40 to 70°C) | |||||
With display and/or AC power supply: -4 to 158°F (-20 to 70°C) | ||||||
Remote sensor junction box: -40 to 212°F (-40 to 100°C) | ||||||
Inputs Power: | 24 VDC (±10%), 0.7 Amps (standard DC Power) 100 to 240VAC ∼(+10%-15%), 50-60Hz, 0.2 Amps (with AC power option). | |||||
Note: Fluctuations of AC and DC power supply are not to exceed ±10% of rating.
|
||||||
Class I Equipment (Electrical Grounding Required for Safety). | ||||||
Installation (Over-voltage) Category II for trnasient over-voltages. | ||||||
Inputs/Outputs: | All outputs and communication circuits are galvanically isolated. | |||||
4-20mA output one is proportional to the measured flow rate. | ||||||
Fault indication per NAMUR NE43. | ||||||
4-20mA output two is programmable for temperature or flow rate. | ||||||
Digital output one is programmable for either pulse (for totalizing flow) or alarms. | ||||||
Output is open collector type, operating voltage 5V to 24V, maximum sinking current: 10mA. | ||||||
The pulse output is proportional to flow rate with a range of 0 to 100Hz. | ||||||
When configured for alarm, the digital output generates an on or off signal. | ||||||
Remote switch input can be configured to reset elapsed time, flow totalizer or switch between gas curves when the 2 gas curve option is ordered. | ||||||
Port: | Mini USB communication port is standard. | |||||
Software: | The free PC-based software tool - FT3 View™ - provides complete configuration, remote process monitoring, and data logging functions. | |||||
Optional serial communication: | HART or Modbus RTU (RS485). | |||||
4-20mA Loop Verification: | Simulation mode used to align 4-20mA output with the input to customer’s PLC/DCS. | |||||
Physical Specs | ||||||
Type | Insertion | Inline | ||||
Sensor Material: | 316 stainless steel standard. Hastelloy C276 optional. | |||||
Enclosure: | NEMA 4X (IP68), Aluminum, dual conduit entries with ¾" NPT or optional M20 x 1.5mm. | |||||
Cabling to remote enclosure: 5-conductor, 18 AWG, twisted, shielded, 100 feet maximum. | ||||||
Retractor Assemblies: | Packing gland assembly: 125 psig (8.6 barg ) max. | |||||
High pressure (crank) retractor: NPT 600 psig (41.4 barg), ANSI 150 flange & ANSI 300 flange, no valve supplied. | ||||||
Installation: | Fox Thermal-supplied compression fitting connects to customer-supplied ¾" female coupling welded to pipe. | Compression fitting included with flow body. |
- 4Matic Valves
- AuCom
- ADVEL
- Aichi Tokei Denki
- Autrol
- AEG
- BEKO TECHNOLOGIES
- BOURNS
- BRUEL & KJAER VIBRO
- Badotherm
- Brooks Instrument
- CHECKLINE
- CS Instruments
- CEIA
- COMET
- CEMB
- DAIICHI ELECTRONICS
- EUROSWITCH
- Econex
- Flownics
- Fox Thermal
- Fotoelektrik Pauly GmbH
- Fireye
- GASTRON
- GINICE
- HBM
- IBA
- IWATSU
- INSERT DEAL
- INDRA
- IPF ELECTRONIC
- IMI NORGREN
- KOGANEI
- KIEPE ELEKTRIK
- KOMETER
- LEINE LINDE
- Lika
- Lapar Valve
- Matsushima
- MTS Sensor
- METRIX
- MARK-10
- MAGNETEK
- MonTech
- mit-UNID-cns
- Maxcess
- MOOG
- NIRECO
- Ohkura
- Puls Power
- PHISHER
- PORA
- PFEIFFER VACUUM
- Pietro Fiorentini
- RIELS
- Rotork
- Redlion
- SUNTES
- SAUTER
- Schenck process
- SensorsONE
- STI
- SENSOREX
- TECLOCK
- TE.MA.VASCONI
- TEMPSENS
- TECH-LAB-SYSTEMS
- Tatronic
- Tek-trol
- Thwing-Albert
- United electric control
- Vibro-Meter®
- von Rohr Armaturen AG
- VEGA
- Vemmtec
- Wilcoxon
- Weintek
- Balluff
- ME SYSTEMSE
- Thiết bị đo lưu lượng
- Thiết bị đo mức
- Thiết bị phát hiện rò rỉ khí
- Thiết bị và hệ thống đo trọng lượng
- Thiết bị phát hiện rò rỉ khí nén
- Thiết bị dùng trong hệ thống điều khiển và tự động hóa
- Flow Technology
- AT2E
- TAY TRANG SPOHN BURKHARDT
- Okazaki
- TWK
- Woma
- MET ONE
- EPI FLOW METER
-
Trực tuyến:15
-
Hôm nay:3837
-
Tuần này:10073
-
Tuần trước:26400
-
Tháng trước:34189
-
Tất cả:3265976